Model 905V O2 Analyzer For Analysis of Oxygen with Limited Headspace |
||||
|
PRIORITY SERVICE AND SUPPORT Parts and repair orders are usually processed on a “same day” basis to minimize analyzer down time. Call (508) 839-3940, email us at sales@quantekinstruments.com, or fill our our brief application form with quote requests or questions. |
Pharmaceutical preparations packaged in vials are often gas-flushed to provide a specific atmosphere in the vial, with defined levels of oxygen, nitrogen or other gases. Depending on the product, these vials can range in size from 1 ml to 250 ml or larger. Small vials present some difficulty for oxygen analysis because the sample volume available is often quite small. A one ml vial, for example, may have only 0.5 ml of headspace gas. For direct analysis with an oxygen analyzer, the instrument must be capable of analyzing very small volumes.
ABOUT THE SENSOR The Model 905V sensor is designed specifically for this purpose. The oxygen sensor internal chamber has a very small volume of about 0.1 cc. The sensor is located directly behind the front panel to eliminate excessive volume. The sensor has in /out ports with a 0.03 in. ID. The vent port of the sensor connects to a short piece of narrow-bore tubing for sample exhaust and introduction of zero or calibration gases.
CALIBRATION SIMPLICITY
The oxygen sensor output is very linear through the entire range of measurement. This allows for a single point calibration to be performed anywhere in the measurement range. Span calibration is accurately done by testing room air, which should give a reading of 20.9% oxygen. Calibration standards can also be used if required by in-house test procedures.
|
Call (508) 839-3940 or email us with quote requests or questions. |
||
| FEATURES | ||||
|
- Analyzes oxygen in all types of
vials, blister package, bottles with limited headspace, and many
others - Battery operated (optional) - Range: 0.01 to 100% oxygen - Removable, low volume sample probe - Economically priced
|
||||
| APPLICATIONS | ||||
|
> Pharmaceutical vials > Blister Packs > Cosmetic Products > Bottles with limited Headspace |
||||
|
LABORATORY OR PRODUCTION LINE ABOUT THE OPTIONAL BATTERY
ABOUT THE WARRANTY
The Model 905V is backed it up with a two year warranty, twice the industry standard. The advanced design allows an output requiring less frequent calibration. It provides a stable, drift-free linearized voltage or current output that is much less susceptible to external electro-magnetic interference than conventional analog electronics.
|
SPECIFICATIONS |
|||
| Call (508) 839-3940, email sales@quantekinstruments.com, or fill our our brief application form with quote requests or questions. | ||||
|
|
|
|||
|
|
All of our products are manufactured in the USA. | |||
|
© 2012, Quantek Instrument, Inc., 183 Magill Drive, Grafton MA 01519 (508) 839-3940 sales@quantekinstruments.com |
||||